KEYILE科译勒 K-PT Integrated Temperature Transmitter/thermocouple
No.K-PT
The integrated digital temperature transmitter is used in conjunction with industrial thermocouples and thermal resistors, and adopts a two-wire transmission method (two wires serve as a common transmission line for power input and signal output). The integrated temperature transmitter converts industrial thermocouple and thermistor signals into 4-20mA and 0-10mA output signals that are linear with the input signal or temperature signal. It can be directly installed in the junction box of thermocouples and thermal resistors to form an integrated structure.
Adopting silicone rubber or epoxy resin sealing structure, it is shock resistant, moisture resistant, and suitable for installation and use in harsh on-site environments.
Installed on-site in junction boxes for thermocouples and thermal resistors, directly outputting 4-20mA and 0-10mA output signals. This not only saves expensive compensation wire costs, but also improves the anti-interference ability during long-distance signal transmission;
The thermocouple transmitter has an automatic compensation function for cold junction temperature;
High precision, low power consumption, wide temperature range for use, stable and reliable operation;
Widely applicable, it can form an integrated on-site installation structure with thermocouples and thermistors, and can also be installed as a functional module in detection equipment and instrument panels for use;
The intelligent temperature transmitter can communicate with the upper computer through a HART modem or remotely manage, configure, monitor variables, calibrate, and maintain the model, scale, and range of the transmitter through handheld devices and PCs;
The intelligent temperature transmitter can adjust the display direction of the transmitter according to the actual needs of the user, and display the medium temperature measured by the transmitter, changes in sensor values, output current, and percentage.
Application Field
A temperature transmitter is a device that converts temperature signals into measurable electrical signals and is commonly used in various fields. Power industry: used to monitor the operating temperature of wind turbines to ensure the stable operation of the power system; Petrochemical industry: can be used to monitor the temperature inside the reactor to avoid explosions or accidents. Environmental monitoring: It can be installed in various environmental monitoring devices to monitor temperature changes in the atmosphere, water bodies, soil, and other environments; In meteorological observation stations, temperature transmitters can monitor air temperature in real time.
Working Principle
Thermocouples or thermal resistance sensors convert the measured temperature into electrical signals, which are then sent to the input network of the transmitter. This network includes relevant circuits such as zeroing and thermocouple compensation. The zero adjusted signal is input to an operational amplifier for signal amplification. The amplified signal is then processed by a V/I converter and output as a 4-20mA DC current; The other path is processed by an A/D converter and displayed in the header. There are two types of linearization circuits for transmitters, both of which use feedback methods. For thermistor sensors, calibrate using positive feedback method, and for thermocouple sensors, calibrate using multi segment line approximation method. There are two display modes. The temperature transmitter for LCD display outputs using a two-wire system, while the temperature transmitter for LED display outputs using a three wire system.
Product Line
Threaded temperature transmitter
Sleeve type temperature transmitter
Standard Hirschman temperature transmitter
Hessman high-temperature type
Probe thermocouple
Technical Specification
1. Technical parameters of 2088 meter digital temperature transmitter
Two wire working mode Input signal: Pt100/-1999.9~600.0 ℃, with one decimal point for the full range. -Within the temperature range of 199.9-600.0 ℃, the zero point and range of the transmission output can be freely set; The button operation and calibration method are simple and fast; The integrated intelligent temperature transmitter adopts a microcontroller circuit, which reliably and accurately completes the collection and conditioning of sensor signals and the output of loop current changes
Power supply
DC13~36V; Load resistance ≤600Ω (when powered by 24V)
Signal range
Pt100/-199.9~600.0℃
Input impedance
>1MΩ
Sampling rate
5 times/second
Measurement accuracy
±0.2%FS
Output accuracy
±0.2%
Display range
-199.9℃~600.0℃
Display mode
0.36" four-digit red digital tube
Temperature drift
<50ppm/℃
Working temperature
-20~80℃
Relative humidity
<85%RH
Protection level
IP65
2. Hirschmann joint technical parameters
On-site display
Without display With display
Output signal
4-20mA
Accuracy
0.5%
Power supply
24V±10%
Temperature measurement range
50°C-600°C
Stable performance
<0.2F.S/year
Case protection
IP65 (waterproof and dustproof)
Case material
304 stainless steel (conventional); others can be customized
3. Thermocouple technical parameters
Product name
Assembled hot couple/resistor
Graduation number
Default K type (can be made into PT100/E/CU50, etc.)
Probe length L1
200 (customizable length)
Probe length R
Default pipe diameter 16mm (others can be customized 8, 10, 12, 20, 25,etc.)
Thread
Thread default M27*2 (customizable)
Cold end length L2
100mm (customizable length)
Transmitter output
4-20mA 1-5V optional (transmitter required)
Special requirements
Transmitter, waterproof, anti-corrosion
Installation requirements
Flange, clamp, straight plug, threaded base
Terminal box length L3
80mm
Terminal box length L4
(default) 76.7mm
T is the absolute value of the measured temperature
Category (code)
Graduati on number
Casing outer diameter (d)
Used temperature (°C)
Maximum operating temperature (°C)
Temperature range
Allowable deviation △t
Nickelchromiumconstantan
E
≥φ3
600
700
0~700
± 2.5℃Or
Nickelchromiumnickelsilicon
K
≥φ3
800
950
0~900
± 2.5℃or
Copperconstantan
T
≥φ3
350
400
<-200
Not regulated
-40~350
± 1℃or
When the temperature changes step by step, the time it takes for the output of the thermocouple to change to 50% of the step change is called the thermal response time, which is represented by T0.5. Insulation resistance When the ambient air temperature is 20±1.5℃ and the relative humidity is not greater than 80%, the insulation resistance value between the wire and the outer sleeve of the insulated armored thermocouple shall comply with the provisions of the following table.
Wire diameter (mm)
Test voltage (V-DC)
Insulation resistance (MΩ.m)
1.5
50±10%
≥1000
>1.5
500±10%
≥1000
The radius of curvature of the flexible armored thermocouple shall not be less than 5 times itsouter diameter. Thermal response time of armored thermocouple:
Thermal response time T0.5S
Shell type
Insulation type
Casing diameter (mm)
2.0
0.4
0.5
3.0
0.6
1.2
4.0
0.8
2.5
5.0
1.2
4.0
6.0
2.0
6.0
8.0
4.0
8.0
Standard Specifications for Outer Diameter and Nominal Length of Armored Thermocouples
φ 8
φ 6
φ 5
φ 4
φ 3
50
50
50
50
50
75
75
75
75
75
100
100
100
100
100
150
150
150
150
150
200
200
200
200
200
250
250
250
250
250
300
300
300
300
300
400
400
400
400
400
500
500
500
500
500
750
750
750
750
750
1000
1000
1000
1000
1000
1250
1250
1250
1250
1500
1500
1500
1500
2000
2000
2000
2000
2500
2500
2500
3000
3000
3000
4000
4000
4000
5000
5000
7500
7500
10000
10000
15000
Armored thermocouple outer diameter d (mm)
Note:
The nominal total length L of the ¢3 insulated armored thermocouple shall not exceed 10000mm.
For armored thermocouples with an outer diameter d≤¢5mm and products with splash-proof or waterproof junction boxes,users should pay attention during installation that the exposed part of the thermocouple must be equipped with auxiliary supports such as brackets to increase rigidity and ensure firmness to prevent the junction box from shaking back and forth and damaging the thermocouple.
4. Probe thermocouple technical parameters
Product name
Probe type thermocouple
Wire length
1~5 meters optional
Mounting thread
M8*1.25mm
Measurement temperature
0~400°C
Probe diameter
Diameters are 0.5, 1.5, 2,2.3, 2.5, 3, 4, 5, 6, 8, 10mm,etc. for selection